Components / Connectors / Power Entry Modules without Filter / KEC
KEC General Information shop
Shop
pdf
pdf-datasheet

Order Number: toset


GST Power Entry Module without Filter: IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole and Voltage Selector

Standard or Medical Fuse drawer
Medical
KEC_screw s/w
Fuse drawer must be ordered separately (see accessories).
KEC_snap s/w
Fuse drawer must be ordered separately (see accessories).
C14
Connector Logo
70° C
Environment_Safety RoHS   Environment_Safety China-RoHS Approval marks UR   Approval marks CSA   Approval marks ENEC 10   Approval marks China

Description

Description

- Panel Mount: Screw-on version from front or rear side, snap-in version from front side
- 3 Functions: Appliance Inlet Protection class I, Fuseholder with interchangeable fuse drawer for Fuse-links 5x20 mm or 6.3x32 mm 1  or 2 pole, with or without voltage selector (step switch)
- Quick connect terminals 4.8 x 0.8 mm

Approvals

- VDE Certificate Number:40030345
- UL File Number:E93617
- CSA File Number:38456
- CCC File Number:2010010204409773

Characteristics

- Available with or without internal connections
- The fuse drawer “Fingergrip” can be removed by hand
For added safety "Extra-Safe" fuse drawers are available
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuse drawer can only be opened with the aid of a tool
The fuseholder is accessible from the equipment front
- Suitable for use in equipment according to IEC/UL 60950

Other versions on request

- Fuse drawer with other voltage values
- For protection class II
- Variant with notch for V-Lock mating Cordsets

References

Alternative: version with line filter KFC

Weblinks

pdf-datasheet, General Product Information , Approvals, CE declaration of conformity, RoHS , CHINA-RoHS , Mating Connectors , e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check, CAD-Drawings , Accessories , Product News , PCN , Detailed request for product

Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.

Top

Technical Data

Ratings IEC 10 A / 250 VAC; 50 Hz
Ratings UL/CSA 13 A / 125 VAC; 60 Hz ¹�?�
Dielectric Strength > 3 kVAC between L-N
> 4 kVAC between L/N-PE
(1 min/50 Hz)
Allowable Operation Temp. -25 °C to 70 °C
Degree of Protection from front side IP 40 acc. to IEC 60529
Protection Class Suitable for appliances with protection class I acc. to IEC 61140
Terminal Quick connect terminals 4.8 x 0.8 mm
Panel Thickness s Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1.5/2/2.5 mm
Material: Housing Thermoplastic, black, UL 94V-0
Appliance Inlet C14 acc. to IEC 60320,
UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I
Fuseholder 1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6,
for fuse-links 5 x 20 or 6.3 x 32 mm
Rated Power Acceptance @ Ta 23 °C 5 x 20: 2.5 W (1 pole)/ 2 W (2-pole) per pole
6.3 x 32: 3.15 W (1 pole)/ 2.5 W (2-pole) per pole
Power Acceptance @ Ta > 23°C Admissible power acceptance at higher ambient temperature see derating curves
Voltage Selector optional, step, 2-4 digits

1) UL/CSA: 1-pole version 13 A, 2-pole version 10 A

Top

Dimension

Dimensions

Screw-on mounting
KEC_schraub_Massbild_Mehransicht
Snap-in mounting
KEC_snap_Massbild_Mehransichten
Top

CAD


Electrical Data

Diagrams

without internal connections
Voltage selector
4-positions, 1-pole
KEA_KEC_Schaltbild_Spwähler_4stellig_1pol_unverdrahdet
without internal connections
Voltage selector
4-positions, 2-pole
KEA_KEC_Schaltbild_Spwähler_4stellig_2pol_unverdrahdet
with internal connections
Voltage selector
4-positions, 1-pole
KEC_Schaltbild_Spwähler_4stellig_1pol_verdrahdet
with internal connections
Voltage selector
4-positions, 2-pole
KEC_Schaltbild_Spwähler_4stellig_2pol_verdrahdet
Voltage selector
3-positions
1-pole
KEC_Schaltbild_Spwähler_3stellig_1pol
Voltage selector
3-positions
2-pole
KEC_Schaltbild_Spwähler_3stellig_2pol
Voltage selector
2-positions
1-pole
KEA_KEC_Schaltbild_Spwähler_2stellig_1pol
Voltage selector
2-positions
2-pole
KEA_KEC_Schaltbild_Spwähler_2stellig_2pol
without voltage selector
1-pole
KEC_Schaltbild_ohne_Spwähler_1pol
without voltage selector
2-pole
KEC_Schaltbild_ohne_Spwähler_2pol
Top

Derating Curves

Fuses
5 x 20 mm (1-pole)
Admissible power acceptance in Watt
Derating_2.5W_5x20_1pol_GST
Ambient air temperature Ta °C
Fuses
5 x 20 mm (2-pole, per pole)
Admissible power acceptance in Watt per pole
Derating_2W_5x20_2pol_GST
Ambient air temperature Ta °C
Fuses
6.3 x 32 mm (1-pole)
Admissible power acceptance in Watt
Derating_3.15W_6.3x32_1pol_GST
Ambient air temperature Ta °C
Fuses
6.3 x 32 mm (2-pole, per pole)
Admissible power acceptance in Watt per pole
Derating_2.5W_6.3x32_2pol_GST
Ambient air temperature Ta °C
Top


Variants

Tabel of Variants

Fuse drawer Fingergrip or Extra-Safe must be ordered separately

Panel mounting Panel Thickness s [mm] Fuseholder Voltage Selector Internally wired Order Number A=Most Popular [?] MOQ [?] PU [?] e-Shop [?] SCHURTER Stock Check [?] Distributor Stock Check [?]
         
Screw - 1-pole - 4303.0031  A  1 50 » » »
Screw - 1-pole 3/4 digits 4303.0091 1 50 » » »
Screw - 1-pole 2 pos. 4303.0211 1 50 » » »
Screw - 1-pole - 4303.1031 1 50 » » »
Screw - 1-pole 3/4 digits 4303.1091 1 50 » » »
Screw - 1-pole 2 pos. 4303.1211 1 50 » » »
Screw - 2-pole - 4303.0001  A  1 50 » » »
Screw - 2-pole 3/4 digits 4303.0061 1 50 » » »
Screw - 2-pole 2 pos. 4303.0181 1 50 » » »
Screw - 2-pole - 4303.1001 1 50 » » »
Screw - 2-pole 3/4 digits 4303.1061 1 50 » » »
Screw - 2-pole 2 pos. 4303.1181 1 50 » » »
Snap-in 1.5 1-pole - 4303.0032 1 50 » » »
Snap-in 1.5 1-pole 3/4 digits 4303.0092 1 50 » » »
Snap-in 1.5 1-pole 2 pos. 4303.0212 1 50 » » »
Snap-in 2 1-pole - 4303.0033 1 50 » » »
Snap-in 2 1-pole 3/4 digits 4303.0093 1 50 » » »
Snap-in 2 1-pole 2 pos. 4303.0213 1 50 » » »
Snap-in 2.5 1-pole - 4303.0034 1 50 » » »
Snap-in 2.5 1-pole 3/4 digits 4303.0094 1 50 » » »
Snap-in 2.5 1-pole 2 pos. 4303.0214 1 1 » » »
Snap-in 1.5 1-pole - 4303.1032 1 50 » » »
Snap-in 1.5 1-pole 3/4 digits 4303.1092 1 50 » » »
Snap-in 1.5 1-pole 2 pos. 4303.1212 1 50 » » »
Snap-in 2 1-pole - 4303.1033 1 1 » » »
Snap-in 2 1-pole 3/4 digits 4303.1093 1 50 » » »
Snap-in 2 1-pole 2 pos. 4303.1213 1 50 » » »
Snap-in 2.5 1-pole - 4303.1034 1 50 » » »
Snap-in 2.5 1-pole 3/4 digits 4303.1094 1 50 » » »
Snap-in 2.5 1-pole 2 pos. 4303.1214 1 50 » » »
Snap-in 1.5 2-pole - 4303.0002  A  1 50 » » »
Snap-in 1.5 2-pole 3/4 digits 4303.0062 1 50 » » »
Snap-in 1.5 2-pole 2 pos. 4303.0182 1 50 » » »
Snap-in 2 2-pole - 4303.0003 1 50 » » »
Snap-in 2 2-pole 3/4 digits 4303.0063 1 50 » » »
Snap-in 2 2-pole 2 pos. 4303.0183 1 50 » » »
Snap-in 2.5 2-pole - 4303.0004 1 50 » » »
Snap-in 2.5 2-pole 3/4 digits 4303.0064 1 50 » » »
Snap-in 2.5 2-pole 2 pos. 4303.0184 1 50 » » »
Snap-in 1.5 2-pole - 4303.1002 1 50 » » »
Snap-in 1.5 2-pole 3/4 digits 4303.1062 1 50 » » »
Snap-in 1.5 2-pole 2 pos. 4303.1182 1 50 » » »
Snap-in 2 2-pole - 4303.1003 1 50 » » »
Snap-in 2 2-pole 3/4 digits 4303.1063 1 50 » » »
Snap-in 2 2-pole 2 pos. 4303.1183 1 50 » » »
Snap-in 2.5 2-pole - 4303.1004 1 50 » » »
Snap-in 2.5 2-pole 3/4 digits 4303.1064 1 50 » » »
Snap-in 2.5 2-pole 2 pos. 4303.1184 1 50 » » »
Most Popular.
Availability for all products can be searched real-time: http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Suffix ".21" corresponds to the version with V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.
Top

Packaging unit

50 Pcs 

Mating Components

Category / Description
4787, SGE GST, PG07, Gerätesteckdose 10A Frontplatte s/w
Appliance Outlet Overview complete
0102, SGE GST, PG07, G-Steckdose 10A/für Kabel
Connector Overview complete
Top
Description
KEC_KFC_KD__CD_Schublade_Fingergrip_mit_SPW
Fusedrawer 3
Top
Top

The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. 22.03.2014