• Newsroom
  • Contact
  • safe&easy
  • DE EN 中文
results out of Read more Products View all results

Share

Share this page

You can share this page with others by sending the URL of the selected page.

Email LinkedIn
productphoto
productphoto
productphoto
productphoto

Series: DF12

Free Sample Request

IEC Appliance Inlet C14 with Filter, Circuit Breaker TA45 (recessed)

Connectors (Inlets/Outlets)

C14
Connector Logo
70° C

Description DF12

Description

  • Panel Mount: Screw-on mounting from front side
  • 3 Functions: Appliance Inlet Protection class I, circuit breaker type TA45 2-pole, Line filter in standard and medical version
  • Quick connect terminals 6.3 x 0.8 mm

Characteristics

  • All single elements are already wired
  • Circuit Breaker non-illuminated or illuminated
  • Suitable for use in equipment according to IEC/UL 60950
    Suitable for use in medical equipment according to IEC/UL 60601-1

Other versions on request

  • Unwired versions
  • Other rocker marking
  • Medical version M80
  • Capacitance CX1
  • Variant with notch for V-Lock mating Cordsets
Date Subcategory Language Title Download
09/08/2018
Flyers English Flyer V-Lock cord-retention safeguard
09/08/2018
White Paper English White Paper Cord retention
16/05/2018
PCN English DF12 PCN
06/04/2018
White Paper English White Paper Mating Connectors English
08/03/2018
Flyers English Flyer Components and Solutions for Medical Equipment
24/11/2017
White Paper English White Paper Protection class II
24/11/2017
White Paper English White Paper Leakage currents
09/09/2017
White Paper English White Paper Power Consumption
15/05/2017
PCS English DF12 PCS
30/09/2016
PCN English Confi Code 5145, DF12, EF12 PCN
28/09/2016
PCN English 5145, DF12, EF12 PCN
20/04/2016
PCN English DF12
20/04/2016
PCN English DF12
20/04/2016
PCN English DF12

Ratings IEC

Ratings IEC


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses

Ratings IEC, UL/CSA
General information on the rated current and the rated voltage at EMC products

Rated Voltage
Rated current
The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families


Approvals

1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz

Ratings UL/CSA

Ratings UL


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses

Ratings IEC, UL/CSA
General information on the rated current and the rated voltage at EMC products

Rated Voltage
Rated current
The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families


Approvals

1 - 15 A @ Ta 40 °C / 250 VAC; 60 Hz

Leakage Current

Leakage Current


The leakage current is an electric current flowing in an undesirable current path. In EMC filters this is done by the applied Y-capacitors, which are used for noise suppression. Information on the amount and classification of leakage currents are explained in detail and are listed in the data sheets.

Leakage Current

standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)

Dielectric Strength

Dielectric Strength


Information abou the maximum permissible voltage, to avoid a voltage breakdown due to insulation damage.


Dielectric Strength

> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)

Allowable Operation Temperature

-10 °C to 55 °C

Climatic Category

Climatic Category


Disposition of components in categories for the assessment of mechanical and electrical properties.

Climatic Category

10/055/21 acc. to IEC 60068-1

IP-Protection

IP-Protection


The IP code consists of a two-digit number, which indicates the respective degree of protection.

The first digit specifies the protection from the penetration of foreign objects, the second digit the protection from water penetration with harmful effects.

Details about IP protection degree can be looked up in the general product information

IP-Protection

from front side IP 40 acc. to IEC 60529

Protection Class

Protection Class


Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information


Insulation cover

Suitable for appliances with protection class I acc. to IEC 61140

Terminal

Terminals


Terminals according IEC Standard.

Detailed information about terminals can be looked up in the date sheet or in the general product information.

Terminal

Quick connect terminals 6.3 x 0.8 mm

Panel Thickness S

Panel Thickness S



See details in drawing

Snapper

Screw: max 8 mm
Mounting screw torque max 0.5 Nm

Material: Housing

Thermoplastic, black, UL 94V-0

appliance inlet/-outlet

appliance inlet/-outlet


Connector type according to IEC 60320-1 resp. IEC 60320-2-2, UL498, CSA C22.2 no.42

Details on connectors and their names can be found in the general product information

Appliance Couplers
Mating Connectors
Term explanation
Special Connector Designs

C14 acc. to IEC 60320-1
UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I

Circuit Breakers

appliance inlet/-outlet


Connector type according to IEC 60320-1 resp. IEC 60320-2-2, UL498, CSA C22.2 no.42

Details on connectors and their names can be found in the general product information

Appliance Couplers
Mating Connectors
Term explanation
Special Connector Designs

Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235
2-pole rocker switch, illuminated or non-illuminated. Optional with undervoltage- or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A

Line Filter

Filter Type


Filter classification according leakage current for easy reading:

Standard: < 0.5 mA
Medical: < 0.1 mA

Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8
Technical Details

MTBF

MTBF


The term MTBF is the English acronym Mean Time Between Failure and describes reliability of a component. The operating time of a system can be calculated based on thementioned value of the component. - The higher this value, the more reliable the component.

MTBF

> 100'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  
Details about Approvals


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: DF12

Approval Logo Certificates Certification Body Description
Approval marks ENEC 10 VDE Certificate Number: 40012935
Approval marks cURus UL UL File Number: E72928


Product standards

Product standards that are referenced

Organization Design Standard Description
Partners IEC_Certification_Body Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Partners IEC_Certification_Body Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Partners IEC_Certification_Body Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements
Partners UL_Certification_Body Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Partners UL_Certification_Body Designed according to UL 1283 Electromagnetic interference filters
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.
Partners IEC_Certification_Body Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG EU Directive RoHS 2011/65/EU
Environment_Safety China_RoHS_50_non_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
 V_Lock_Logo SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.
Environment_Safety Medical.jpg SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1

Preview
 

Picture(s) Selection of product pictures to display a specific variant of the type

Type
 

Type Corresponds to a product series and includes various distinct variants. On the type of descriptive data are summarized, eg in the data sheet

Order Number
 

Order Number Unique part number for placing an order

Configuration key
 

Configuration key The configuration key of a product consists of the composite key values, which describe the different kinds of attribut distinction.

Comment
 
Model Description
 

Model Description Abbreviated description of the CAD model

IGS
 

IGS Also mentioned as IGES ( Initial Graphics Exchange Specification). Common program indipendent interchange format for 3D CAD data.

Step
 

Step Also mentioned as STEP ( Standard for the Exchange of Product Model Data). Common program indipendent interchange format for 3D CAD data standardized according ISO standard.

Parasolid
 

Parasolid Parasolid modeling kernel is a 3D CAD systems. It is developed by a separate business unit within the Unigraphics Solutions (UGS), now Siemens PLM Software.

DXF
 

DXF (Drawing Interchange Format) is a specified by the Autodesk file format for CAD data exchange, and was developed for the 2D-CAD program AutoCAD. A DXF file describes a CAD model as plain text to the ASCII standard.

DF12
DF12.0012.5110.1 DF12.0012.5310.1 DF12.0022.7110.1 DF12.0031.9110.1 DF12.0031.9310.1 DF12.0423.6110.1 DF12.0470.7110.1 DF12.0470.7310.1 DF12.0470.9310.1 DF12.0586.5110.1 DF12.0646.6110.1 DF12.0778.7110.1 DF12.0778.7110.2 DF12.0847.5310.1 DF12.0861.7110.1 DF12.0885.9110.1 DF12.0885.9310.1 DF12.0890.9310.1 DF12.0979.7310.1 DF12.0991.5110.1 DF12.0991.5110.2 DF12.0991.5310.1 DF12.1034.9310.1 DF12.1089.9110.1 DF12.1089.9310.1 DF12.1250.3310.2 DF12.1250.7110.1 DF12.1297.5110.1 DF12.1356.4110.1 DF12.1384.7310.1 DF12.1488.5310.1 DF12.1593.7310.1 DF12.1682.9110.1 DF12.1938.9310.1 DF12.2420.9310.1 DF12.2421.4110.1 DF12.2600.9310.1 DF12.2770.9110.1 DF12.2837.9310.1 DF12.2851.9110.1 DF12.2851.9310.1 DF12.3000.9310.1 DF12.3166.2110.1 DF12.3417.9110.1 DF12.3593.7110.1 DF12.3609.3310.1 DF12.3635.3110.1 DF12.3645.9310.1 DF12.3673.7110.1 DF12.3673.7310.1 DF12.3673.9310.1 DF12.3689.3310.1 DF12.3690.5310.1 DF12.3732.4310.1 DF12.3737.6310.1 DF12.3754.1110.1 DF12.3803.2110.1
DF12-XXXXXXXXXX-XXX-XXXX-0X-XX CAD-Model shows variation Terminal 6.3x0.8 mm

Dimensions [mm]

Screw-on mounting

* --- Version TA45 with undervoltage release

Diagrams

Standard version

1) Line
2) Load
Medical version (M5)

1) Line
2) Load

Technical Data of Filter-Components

Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ]
1 Standard 2 x 11 100 2.2 1
2 Standard 2 x 4 100 2.2 1
3 Standard 2 x 2.5 100 2.2 1
4 Standard 2 x 1.6 100 2.2 1
6 Standard 2 x 0.7 100 2.2 1
8 Standard 2 x 0.6 100 2.2 1
10 Standard 2 x 0.4 100 2.2 1
15 Standard 2 x 0.1 100 2.2 1
2 Medical (M5) 2 x 4 100 - 1
3 Medical (M5) 2 x 2.5 100 - 1
4 Medical (M5) 2 x 1.6 100 - 1
6 Medical (M5) 2 x 0.7 100 - 1
8 Medical (M5) 2 x 0.6 100 - 1
10 Medical (M5) 2 x 0.4 100 - 1
15 Medical (M5) 2 x 0.1 100 - 1

Attenuation Loss

1 A

2 A

3 A

4 A

6 A

8 A

10 A

15 A

1 A

2 A

3 A

4 A

6 A

8 A

10 A

15 A



Alternative: version without line filter (1)

[Swipe to the left and right for more options]

Substitute for type (1)

[Swipe to the left and right for more options]

Alternative: Standard version (0)

[Swipe to the left and right for more options]

Mating Outlets/Connectors (14)

[Swipe to the left and right for more options]

4787

IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal

4788

IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal

5091

IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal

4782

4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4022

4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13

4785

4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4300-06

4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13

4012

4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13

4781

IEC Connector C15 for hot conditions 120°C, Rewireable, Straight

8101

IEC Connector C15, Rewireable, Straight

4784

IEC Connector C15 for hot conditions 120°C, Rewireable, Angled

0102-G

IEC Connector C15A, Rewireable, Straight, gold-plated terminals

4771

IEC Connector C15A for very hot conditions 155°C, Rewireable, Straight

4772

IEC Connector C15A, Rewireable, Angled

Mating Outlets/Connectors shuttered (1)

[Swipe to the left and right for more options]

VAC13KS

VAC13KS, Overview, diverse Connector IEC C13, cord end:

Accessories (2)

[Swipe to the left and right for more options]


www.schurter.com
en
en
prod //cdn.schurter.com