• Newsroom
  • Contact
  • safe&easy
  • DE EN 中文
results out of Read more Products View all results

Share

Share this page

You can share this page with others by sending the URL of the selected page by email.

Email
productphoto
productphoto
productphoto
productphoto

Series: FMAD CEE

New_Logo Free Sample Request

1-stage filter with 3-phase CEE connector

3 Variants



Approvals and Compliances

Description FMAD CEE

Description

  • 3 Phase CEE Connector with Filter
  • Easy and time saving handling

Unique Selling Proposition

  • First CEE power entry module with EMC filter
  • Easy prewired solution
  • Universal flange for front or rear mounting
  • Optimal filter position direct on the power entry

Approvals

  • Approval Reference Type: FMAD CEE
  • UL File Number: E72928
  • ENEC File Number: SE/09137-4
Date Category Subcategory Title Download

Rated Current

The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses

Ratings IEC, UL/CSA
General information on the rated current and the rated voltage at EMC products

Rated Voltage
Rated current
The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families


Approvals

16 - 32 A @ Ta 40 °C

Rated voltage

The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses

Ratings IEC, UL/CSA
General information on the rated current and the rated voltage at EMC products

Rated Voltage
Rated current
The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families


Approvals

277/480 VAC, 50/60 Hz

Approval for

Approvals indicate the conformity of the products with the national testing institution requirements by listing of the relevant approval logos.

appr =
Approvals
The link leads you to the search mask where you can query for certificates of the selected products.

Approvals
Detailed information about Approvals will be documented in the general product informations.

Details about Approvals

16 - 32 A / 277/480 VAC

Overload Current

1.5 x Ir

Leakage Current

The leakage current is an electric current flowing in an undesirable current path. In EMC filters this is done by the applied Y-capacitors, which are used for noise suppression. Information on the amount and classification of leakage currents are explained in detail and are listed in the data sheets.

Leakage Current

industrial < 10 mA (440 V / 50 Hz)

Dielectric Strength

Information abou the maximum permissible voltage, to avoid a voltage breakdown due to insulation damage.


Dielectric Strength

277/480 VAC:
2.25 kVDC between L-L
1.7 kVDC between L-N
3 kVDC between L-PE
Test voltage (2 sec)

Number of Filter Stages

Quality of a filter

1-stage

Weight

 1.4 kg

Material: Housing

Metal 

Sealing Compound

UL 94V-0 

Mounting

Screw-on mounting on chassis 

Terminal

AMP = standardized connector systems and contacts
Abbreviation for "Zero Insertion Force". The so-called ZIF connector takes the flexprint cable without effort, mostly with locking. The advantage of this connector is the gentle treatment of the pin

Screw clamps 

Operating Temperature

-40 °C to 85 °C

Climatic Category

Disposition of components in categories for the assessment of mechanical and electrical properties.

Climatic Category

40/085/21 acc. to IEC 60068-1

Degree of Protection

Disposition of components in categories for the assessment of mechanical and electrical properties.

Climatic Category

IP 20 acc. to IEC 60529

Protection Class

Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information


Insulation cover

Suitable for appliances with protection class I acc. to IEC 61140

MTBF

The term MTBF is the English acronym Mean Time Between Failure and describes reliability of a component. The operating time of a system can be calculated based on thementioned value of the component. - The higher this value, the more reliable the component.

MTBF

> 200'000 h acc. to MIL-HB-217 F


Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  
General Product Information

Preview
 

Picture(s) Selection of product pictures to display a specific variant of the type

Type
 

Type Corresponds to a product series and includes various distinct variants. On the type of descriptive data are summarized, eg in the data sheet

Order Number
 

Order Number Unique part number for placing an order

Configuration key
 

Configuration key The configuration key of a product consists of the composite key values, which describe the different kinds of attribut distinction.

Comment
 
Model Description
 

Model Description Abbreviated description of the CAD model

IGS
 

IGS Also mentioned as IGES ( Initial Graphics Exchange Specification). Common program indipendent interchange format for 3D CAD data.

Step
 

Step Also mentioned as STEP ( Standard for the Exchange of Product Model Data). Common program indipendent interchange format for 3D CAD data standardized according ISO standard.

Parasolid
 

Parasolid Parasolid modeling kernel is a 3D CAD systems. It is developed by a separate business unit within the Unigraphics Solutions (UGS), now Siemens PLM Software.

DXF
 

DXF (Drawing Interchange Format) is a specified by the Autodesk file format for CAD data exchange, and was developed for the 2D-CAD program AutoCAD. A DXF file describes a CAD model as plain text to the ASCII standard.

FMAD CEE
FMAD-T4QT-1660.EU
Model with 415V - 16A socket
FMAD CEE
FMAD-T4QT-3060.US
Model with 480V - 30A - US socket
FMAD CEE
FMAD-T4QT-3260.EU
Model with 415V - 32A socket

Dimension [mm]

Case QT1

1) Line
2) Load
3) Blue
4) Yellow-Green
Case QT3

1) Line
2) Load
3) Blue
4) Yellow-Green

Diagrams

1) Line
2) Load

Attenuation Loss

16 A

30 / 32 A


Short Table of Variants FMAD CEE


Rated Current @ Ta 50°C (40°C) [A] Rated Voltage [VAC] Powerloss @ 25°C, 50Hz [W] Order Number

The link on the respective order number refers to a separat tab with specific detailed information .

This assures better readable information of the selected product.
Change to the tab All Products in order to show details of another variant.

This approach offers to use generic alias link to the product details:

www.schurter.xx/art/ [Order Number]

where the following variables are used:
- xx is the country specific domain
- [Order Number]

A=Most Popular

Most popular products have the following customer benefits:

- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle

Contact us for availability on other product variants, lead-times vary:

Contact-Form
Availability for all products can be searched real-time. Enter part number and required quantity:

Stock Check SCHURTER

Free Sample

Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

The following links reffers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.

The
Distributor Stock Check

Stock Check Distributor

...
 
16 240/415 5.6 FMAD-T4QT-1660.EU  A  ...
30 277/480 4.3 FMAD-T4QT-3060.US  A  ...
32 240/415 4.9 FMAD-T4QT-3260.EU  A  ...

Most Popular.

1) Nominal leakage current acc. to IEC60950 - 5.2.5. under normal operating conditions. Note: worst case leakage current acc. to IEC60950 - Annex G4 (situation with two interrupted lines) can be much higher.

2) Maximum conductor cross section (wire gauge) to be used; a comparative table for AWG and mm² values can be found in the general product information www.schurter.com/emc_info



en
prod //d1r84oewyu4qpi.cloudfront.net